MODIS_ACDNC Adiabatic Cloud Droplet Number Concentration daily value

doi:10.1594/WDCC/MODIS_CDNC

Quaas, Johannes; Boucher, Olivier

ExperimentDOI
Summary
Cloud droplet number concentration is derived from MODerate Resolution Imager Spectroradiometer (MODIS) data from NASA's Terra platform.
The MOD08_D3 daily data (collection 4 processing stream) on a grid of 1x1 degrees is used, which can be downloaded from http://eosdata.gsfc.nasa.gov/daac-bin/MODIS/Data_order.pl.
From the joint histrogram of cloud optical thickness (COD) and cloud-top droplet effective radius (CDR) for liquid water clouds, CDNC is diagnosed assuming adiabatic clouds.
Project
MODIS (MODIS data)
Contact
Prof. Dr. Johannes Quaas (
 johannes.quaas@nulluni-leipzig.de
0000-0001-7057-194X)
Location(s)
World (general)
Spatial Coverage
Longitude -180 to 180 Latitude -90 to 90 Altitude: 0 m
Temporal Coverage
2000-03-01 to 2005-02-28 (calendrical)
Use constraints
unrestricted
Data Catalog
World Data Center for Climate
Size
452.88 MiB (474878840 Byte)
Format
NetCDF
Status
completely archived
Creation Date
Cite as
Quaas, Johannes; Boucher, Olivier (2005). MODIS_ACDNC Adiabatic Cloud Droplet Number Concentration daily value. World Data Center for Climate (WDCC) at DKRZ. https://doi.org/10.1594/WDCC/MODIS_CDNC

BibTeX RIS
Description
CDNC data is derived from MODIS-retrieved cloud optical thickness and cloud-top droplet effective radius. Liquid water clouds only are used, and COD and CDR are restricted to their most reliable values (4um <= CDR <= 30um and 4 <= COD <= 70; Nakajima and King, J. Atmos. Sci., 1990).
However, for MODIS-retrieved CDR, problems are known (Breon and Doutriaux-Boucher, IEEE Trans. Geosci. Remote Sens., 2005). The assumption of adiabacity may not necessarily be valid, even though large regions are considered.
We recommend to use CDNC for statistical studies rather than to rely on absolute accuracy in single regions or short time-periods.
Description
Missing values occur due to entirely clear sky grid-boxes (where thus no cloud retrieval is possible) or due to other retrieval problems (e.g.,instrument failure or unsuitable viewing geometries).
Description
Summary:
Findable: 6 of 7 level;
Accessible: 2 of 3 level;
Interoperable: 3 of 4 level;
Reusable: 4 of 10 level
Method
F-UJI online v2.2.1 automated
Method Description
Checks performed by WDCC. Metrics documentation: https://doi.org/10.5281/zenodo.4081213 Metric Version: metrics_v0.5
Method Url
Result Date
2022-12-13
Contact typePersonORCIDOrganization
-

Is described by

[1] DOI Quaas, J.; Boucher, O.; Lohmann, U. (2005). Constraining the total aerosol indirect effect in the LMDZ and ECHAM4 GCMs using MODIS satellite data. doi:10.5194/acpd-5-9669-2005

Attached Datasets ( 1 )

Details for selected entry

Parent project(s)

MODIS data

[Entry acronym: MODIS_CDNC] [Entry id: 2066450]